──Oct 06 , 2021Induction motor lead wire heating causes (1)

       Motor wiring is an important part of the motor products, in general, if the induction motor wiring is selected in accordance with the current density of the specification, there will be no heating problem, but in the actual production, there will be such problems from time to time, today, Senli Motor Xiaobian will take you to a simple understanding.

       If orderedThree-phase asynchronous motorAll the lead wires have heating problems, then we need to consider whether the conductor diameter of the lead wire is in line with it, excluding the installation error, which can basically be attributed to the manufacturing quality of the motor products;

       If an individual lead wire produces heat, it may be caused by the local occurrence of poor lead wire, which may occur in the position where the motor winding is connected with the lead wire, and more often occurs inAsynchronous motorThe position where the lead cable is fixed with the connector, or where the connector is fixed with the patch board.

Three-phase asynchronous motor manufacturers motor products

       The above is a typical manufacturing quality problem, but for the connection of the wire connection and the patch board, it is more often directly related to the introduction of the power line connection.

       In the process of induction motor manufacturing, the necessary anti-loosening measures have been taken in the fixing link of the patch board, such as the use of anti-loosening elastic washers; In the installation of the motor, if the necessary anti-loosening measures are not taken, or the heat and vibration during the operation of the motor lead to poor contact at the fixed position, it will lead to heating problems.

       Three-phase asynchronous motor manufacturersSenli motor, from shaft processing to the whole machine assembly are completed independently; Available if needed1688Search factory name "Shengzhou Chaoli Electric Appliance Factory" , Or online consultation message, we will have business personnel to get in touch with you, you can also contact us directly0575-8378-1127.