In the short-circuit test, we need to control the rotor with brakable equipment, so that the rotor of the three-phase asynchronous motor is fixed, and then the output voltage of the three-phase voltage regulator is gradually increased from zero. When the current reaches the rated current of the motor, the boost voltage is stopped, and the voltage is called the short-circuit voltage.
For example, the rated voltage is380VWhen the motor is short circuited, the voltage display is generally in75-90Between volts, if the short circuit voltage is too high, it means that the leakage reactance is too large, which isThree-phase asynchronous motorThe stator winding is caused by too many turns; The short circuit voltage is too low, indicating that the leakage reactance is too small, which is caused by too few turns of the stator winding.
If the three-phase current is not balanced, you can slowly turn the rotor; If the size of the three-phase current changes in turn, the rotor may be broken, and the rotor should be checked.
Senli Motor,20Focus on the development and production of electric motors. Available if needed1688Search factory name "Shengzhou Chaoli Electric Appliance Factory" , Or online consultation message, we will have business personnel to get in touch with you, you can also contact us directly0575-8378-1127.