Shengzhou Chaoli Electric Appliance Factory

Frequently asked questions

──Mar 18 , 2021Motor maintenance knowledge: Common faults and troubleshooting methods of three-phase asynchronous motors (4)

       Today we are talking aboutThree-phase asynchronous motorCauses and elimination of problems such as sound and vibration frequency during operation:

       Note: If the motor fails, please be sure to be handled by technical personnel, strict non-technical personnel privately, otherwise it may cause personal and property losses.

       one. The running sound is abnormal,Abnormal sound
  
       1. Fault cause analysis  
       ①The rotor rubs against the stator insulation paper or the slot wedge
       ②Bearing wear or oil in the sand and other foreign matter
       ③The rotor core is loose
       ④Bearing oil shortage
       ⑤Air duct packing or fan hood
       ⑥Rotor core rub
       ⑦The power supply voltage is too high or unbalanced
       ⑧The stator windings are misconnected or short-circuited
 
       2. troubleshooting
       ①Trim the insulation and trim the wedge
       ②Replace bearings or clean bearings
       ③Check and repair the rotor core
       ④refuel
       ⑤Clean the air duct; remount
       ⑥Remove scratches inside small rotors if necessary
       ⑦Check and adjust the power supply voltage
       ⑧Remove stator winding fault. 
Three-phase asynchronous motor
       two.In operation Three-phase asynchronous motorHigh vibration
 
       1. Fault cause analysis 
       ①Bearing clearance is too large due to wear
       ②The air gap is uneven
       ③Rotor unbalance
       ④Shaft bending
       ⑤The core is deformed or loose
       ⑥Coupling (pulley) center not calibrated
       ⑦Fan unbalance
       ⑧Insufficient housing or foundation strength
       ⑨The anchor screw of the motor is loose
       ⑩Cage rotor open welding break; The winding rotor is open; The stator winding is faulty.
 
       2. troubleshooting  
       ①Repair bearings and replace them if necessary
       ②Adjust the air gap to make it even
       ③Correct rotor dynamic balance
       ④Alignment of the rotating shaft
       ⑤Correcting overlapping core
       ⑥Recalibrate it to conform to the regulations
       ⑦Check the fan, correct the balance, and correct its geometry
       ⑧reinforce
       ⑨Tighten the anchor screws
       ⑩Repair the rotor winding; Repair the stator winding 

       Three-phase asynchronous motorRegular maintenance and overhaul is needed to avoid and reduce sudden damage accidents.
       " Mori machine"Brand affiliation Shengzhou Chaoli electric appliance factoryAfter years of accumulation of technical and service experience, timely grasp of customer needs Mori machineProducts have been innovative and flexible, the concept of environmental protection and energy saving and motor design integrated, rich product research and development experience to ensure Mori machineProducts of high reliability and high performance have passed the EUCECertification,3CECertification and third party quality testing.
BACK
PREV

Torque motor selection tips

NEXT

Mori Motor: Brief description of torque motor